All alarms should be reported on a daily basis. Also, all alarms should be recorded prior to being cleared.
Alarms higher than 255 are APX only; Alarms 255 and lower are used by both Advance and APX Control Systems, although some Alarms will be specific to a particular controller or model. Alarms marked with an asterisk (*) are for Advance units only.
An asterisk (*) in the ACTION column indicates that specific alarm can be reset by placing the START/RUN – OFF switch in the OFF position and then back in the START/RUN POSITION.
The information provided herein is a recommendation only. Always follow your company’s guidelines whenever an alarm occurs.
Green = Notification Alarm |
Yellow = Caution Alarm |
Red - Shutdown Alarm (or Alarm Only as configured) |
![]() |
![]() |
Alarm |
Description |
Action |
Electrical Alarms (continued) |
|
|
00102 |
Evap Motor Overload C3 |
Report and repair immediately |
00103 |
Check C2 Heater 1 Circuit |
Reset*; report reactivation |
00104 |
Check C2 Heater 2 Circuit |
Reset*; report reactivation |
00105 |
Check C3 Heater 1 Circuit |
Reset*; report reactivation |
00106 |
Check C3 Heater 2 Circuit |
Reset*; report reactivation |
00107 |
Future Use |
|
00108 |
Future Use |
|
00109 |
Check Evaporator Contactor Cicuit |
Reset*; report reactivation |
00110 |
Check C2 Evaporator Circuit |
Reset*; report reactivation |
00111 |
Check C3 Evaporator Circuit |
Reset*; report reactivation |
00112 |
Future Use |
|
00113 |
Future Use |
|
00114 |
Check LIV Circuit |
Reset*; report reactivation |
00121 |
Check Ambient Air Sensor |
Check and repair at end of trip |
00122 |
Check Return Air Sensor |
If shut down, repair immediately. Otherwise, report and repair at end of trip |
00123 |
Check Supply Air Sensor |
|
00124 |
Check Defrost Termination Sensor |
Check and repair at end of trip |
00125 |
Check Discharge Temp Sensor |
Check and repair at end of trip |
00126 |
Low Fuel Alarm |
Check and repair at end of trip |
00127 |
Check Suction Temp |
Check and repair at end of trip |
00128 |
Low Unbalanced AMP |
Check and repair at end of trip |
00129 |
Check Coolant Temp |
Check and repair at end of trip |
00130 |
Check RPM Sensor |
If shut down, repair immediately. Otherwise, report and repair at end of trip |
00131 |
Check Evaporator Outlet Sensor |
Check and repair at end of trip |
00132 |
Check Defrost Termination Sensor |
Check and repair at end of trip |
00133 |
Check Remote Sensor 1 |
Check and repair at end of trip |
00134 |
Check Remote Sensor 2 |
Check and repair at end of trip |
00135 |
Check Remote Sensor 3 |
Check and repair at end of trip |
00136 |
Check C2 Supply Air |
Check and repair at end of trip |
00137 |
Check C2 Return Air Sensor |
Reset*; report reactivation |
00138 |
Check C3 Return Air Sensor |
Reset*; report reactivation |
00139 |
Check C2 Defrost Termination Sensor |
Check and repair at end of trip |
00140 |
Check C3 Defrost Termination Sensor |
Check and repair at end of trip |
Pretrip Alarms |
|
|
00141 |
Pretrip Aborted by User |
Report and repair immediately |
00143 |
Check Clutch Circuit |
Report and repair immediately |
00144 |
Check UL1 Circuit |
Report and repair immediately |
00145 |
Check Speed Circuit |
Report and repair immediately |
00146 |
Check C2 Heater 1 Circuit |
Report and repair immediately |
00147 |
Check C2 Heater 2 Circuit |
Report and repair immediately |
00148 |
Check SV 1 Circuit |
Report and repair immediately |
00150 |
Check SV 4 Circuit |
Report and repair immediately |
00151 |
Check Engine Preheat |
Report and repair immediately |
00152 |
Check FSA Circuit |
Report and repair immediately |
00153 |
Check Return Air Sensor |
Report and repair immediately |
00154 |
Check Supply Air Sensor |
Report and repair immediately |
00155 |
Check Coolant Temp |
Report and repair immediately |
00156 |
Not Used |
Report and repair immediately |
Alarm |
Description |
Action |
Pretrip Alarms (continued) |
|
|
00157 |
Check Battery Circuit |
Report and repair immediately |
00158 |
Check Ambient Sensor |
Report and repair immediately |
00159 |
Check Defrost Termination Sensor |
Report and repair immediately |
00160 |
Check Discharge Temp Sensor |
Report and repair immediately |
00161 |
Check Suction Temp |
Report and repair immediately |
00162 |
Check Auto Fresh Air |
Report and repair immediately |
00163 |
Check C3 Heater 1 Circuit |
Report and repair immediately |
00164 |
Check UL 2 Circuit |
Report and repair immediately |
00165 |
Cannot Pump Down |
Report and repair immediately |
00166 |
Check C2 Supply Air |
Report and repair immediately |
00167 |
Check C3 Heater 2 Circuit |
Report and repair immediately |
00168 |
Not Used |
Report and repair immediately |
00169 |
Not Used |
Report and repair immediately |
00170 |
Check LIV Circuit |
Report and repair immediately |
00171 |
System Not Equalized |
Report and repair immediately |
00172 |
Check Bypass |
Report and repair immediately |
00173 |
Check Economizer Circuit |
Report and repair immediately |
00174 |
No Low Speed |
Report and repair immediately |
00175 |
No High Speed |
Report and repair immediately |
00176 |
Not Used |
Report and repair immediately |
00177 |
Check Evaporator Superheat |
Report and repair immediately |
00178 |
Check UL 1 |
Report and repair immediately |
00179 |
Check LIV |
Report and repair immediately |
00180 |
Check SMV |
Report and repair immediately |
00181 |
Check SV 4 |
Report and repair immediately |
00182 |
Check SV 1 |
Report and repair immediately |
00183 |
Check SV 3 |
Report and repair immediately |
00184 |
Check C2 Evaporator Fan |
Report and repair immediately |
00185 |
Check C3 Evaporator Fan |
Report and repair immediately |
00186 |
Check Evaporator Outlet |
Report and repair immediately |
00187 |
Check Heater 1 Circuit |
Report and repair immediately |
00188 |
Check Heater 2 Circuit |
Report and repair immediately |
00189 |
Check Evaporator Fan Motor |
Report and repair immediately |
00190 |
Check Condenser Fan |
Report and repair immediately |
00191 |
Check UL 2 |
Report and repair immediately |
00192 |
Check SV 2 |
Report and repair immediately |
00194 |
High Suction Pressure |
Report and repair immediately |
00195 |
Low Suction Pressure |
Report and repair immediately |
00196 |
High Discharge Pressure |
Report and repair immediately |
00197 |
Check Clutch |
Report and repair immediately |
00198 |
Low Discharge Pressure |
Report and repair immediately |
00199 |
Check C2 RAT |
Report and repair immediately |
00200 |
Check UL 1 Cylinder |
Report and repair immediately |
00201 |
Check UL 2 Cylinder |
Report and repair immediately |
00202 |
High Side Leak |
Report and repair immediately |
00203 |
Check Discharge Check |
Report and repair immediately |
00204 |
Low Suction Pressure |
Report and repair immediately |
00205 |
Check Defrost Termination Sensor |
Report and repair immediately |
00206 |
Check Condenser Fan Motor 1 Circuit |
Report and repair immediately |
00207 |
Check Compressor Contactor Circuit |
Report and repair immediately |
00208 |
Check Generator Contactor Circuit |
Report and repair immediately |
00209 |
Check Standby Contactor Circuit |
Report and repair immediately |
Alarm |
Description |
Action |
Pretrip Alarms (continued) |
|
|
00210 |
Check C3 RAT |
Report and repair immediately |
00211 |
Check C2 Defrost Termination Sensor |
Report and repair immediately |
00212 |
Check C3 Defrost Termination Sensor |
Report and repair immediately |
Maintenance Alarms |
|
|
00223 |
Maintenance Hour Meter- Total Diesel |
Check and repair at end of trip |
00224 |
Maintenance Hour Meter- Total Standby |
Check and repair at end of trip |
00225 |
Maintenance Hour Meter- Total Switch |
Check and repair at end of trip |
00226 |
Maintenance Hour Meter 1 |
Check and repair at end of trip |
00227 |
Maintenance Hour Meter 2 |
Check and repair at end of trip |
00228 |
Maintenance Hour Meter 3 |
Check and repair at end of trip |
00229 |
Maintenance Hour Meter 4 |
Check and repair at end of trip |
00230 |
Maintenance Hour Meter 5 |
Check and repair at end of trip |
Microprocessor Alarms |
|
|
00232 |
Non Valid Setpoint |
Reset*; report reactivation |
00233 |
Non Valid Model Number |
Reset*; report reactivation |
00237 |
Non Valid Functional Parameter |
Reset*; report reactivation |
00238 |
Non Valid Configuration Parameter |
Reset*; report reactivation |
00242 |
Discharge Pressure Transducer Calibration |
Reset*; report reactivation |
00243 |
Suction Pressure Transducer Calibration |
Reset*; report reactivation |
00244 |
Economizer Pressure Transduer Calibration |
Reset*; report reactivation |
00245 |
Cannot Save Settings |
Reset*; report reactivation |
00246 |
Eprom Write Failure |
Reset*; report reactivation |
00248 |
Configuration Error |
Reset*; report reactivation |
00249 |
Microprocessor Error |
Reset*; report reactivation |
00255 |
System Failure |
Reset*; report reactivation |
Alarm |
Description |
Action |
EES Alarms (continued) |
|
|
26214 |
EES ECU Temp Low |
Reset*; report reactivation |
26215 |
EES ECU Temp High |
Reset*; report reactivation |
26216 |
EES No Temp Rise |
Reset*; report reactivation |
26217 |
EES System Failure |
Report and repair immediately |
26218 |
EES System Overtemp |
Report and repair immediately |
26219 |
EES Temp Sensor Drift |
Reset*; report reactivation |
26220 |
EES Back Pressure |
Reset*; report reactivation |
26221 |
EES Frequent |
Reset*; report reactivation |
26222 |
EES Back Pressure Offset Exceeded |
Reset*; report reactivation |
Engine Alarms |
|
|
26300 |
ENCU Comm Failure (TDO Only) |
Report and repair immediately |
26301 |
ENCU Alarm (TDO Only) |
Reset*; report reactivation |
26302 |
ENCU Alarm (TDO Only) |
Reset*; report reactivation |
26500 |
Incompatible ENCU |
Report and repair immediately |
Comm Alarms |
|
|
27100 |
Loss of Communication to Comm Module |
Report and repair immediately |
27200 |
Loss of Communication to Optional Comm Module |
Report and repair immediately |
28001 |
No Comm From Fuel |
Reset*; report reactivation |
28002 |
No Comm From Door |
Reset*; report reactivation |
28003 |
Invalid 3rd Party Door |
Reset*; report reactivation |
28004 |
Invalid 3rd Party REMS1 |
Reset*; report reactivation |
28005 |
Invalid 3rd Party REMS2 |
Reset*; report reactivation |
28006 |
Invalid 3rd Party REMS3 |
Reset*; report reactivation |
28007 |
Invalid 3rd Party REMS4 |
Reset*; report reactivation |
28008 |
No Comm From Fuel Flow Meter |
Reset*; report reactivation |
29000 |
Alternator Electric Issue |
Report and repair immediately |
29001 |
Alternator High Temp |
Report and repair immediately |
29002 |
Alternator Belt Broken |
Report and repair immediately |
29003 |
Alternator Belt Slip |
Reset*; report reactivation |
29004 |
LIN Comm Error |
Reset*; report reactivation |
29005 |
LIN Comm Timeout |
Reset*; report reactivation |
29006 |
No Comm to Alternator |
Report and repair immediately |
29007 |
Power Frequency |
Reset*; report reactivation |